Stock code

300693

Battery module testing equipment series

Module power battery testing equipment has high energy density, wide output voltage range, the lowest discharge voltage can reach 5V, compatible with a variety of models of module battery test response speed, efficient energy feedback and other excellent performance, can be compatible with a variety of voltage and current levels of battery module for electrical performance test.

The product application

  • Battery cell production
  • Research on the test
  • Quality inspection
  • Step recovery, etc.
  • Minor changes between millimeters can also be easily explored.

    Accuracy of voltage and current is better than 0.05%F.S., automatic selection of current gear. According to the output range of different equipment models, it can be equipped with multi-current gear selection, and automatically select the most suitable current gear according to published parameters. Maximize the accuracy of test data to provide an accurate data basis for battery analysis.

    Condition simulation function

    The device simulates any current/power waveform of the battery during the actual driving process such as starting, climbing and braking, providing reliable and comprehensive data to help customers shorten the battery development/validation cycle.
  • 20ms

    Minimum time interval
  • excel

    Support EXCEL import of current/power conditions
  • 3 millions

    Working condition of article number
  • Fast current response, airtight

    Output current quickly reach the set value, support a variety of high-speed dynamic waveform and working condition simulation test.
  • ≤5ms

    Current response time
  • ≤10ms

    Current conversion time
  • Support a variety of fast dynamic waveform simulation test
  • Equipment linkage, a variety of environments catch up

    The equipment can be linked with BMS, water cooler, environment box, temperature, pressure and other sensors to form a high-performance detection system; The unified control of BTS software accurately evaluates the electrical performance of battery packs in various extreme environments, and uniformly controls and controls test equipment, making it convenient and simple to operate.

    High feedback efficiency facilitates green production

    The energy is transferred to the charging cell for direct utilization and feedback to the power grid. It has no pollution to the power grid, and can effectively reduce the power consumption of the power grid, save power, and greatly reduce the production cost.
  • >0.99

    The power factor
  • 90%

    Feedback
  • ≤3%

    Harmonic content
  • DCIR test

    The device provides a test method for battery DC internal resistance. It supports setting a value point and automatically obtains the required test result without manual calculation.

    BTS software, human-computer interaction one step ahead

    Battery detection and formation software is the background control system of battery production and testing system, mainly responsible for process step editing, test control, real-time data display, test process data recording and data analysis.
  • Centralized monitoring of multiple channels on different devices.
  • A variety of complex work step editing, multiple work step conditions combination judgment.
  • Generate data reports based on custom templates.
  • Data recording time:10ms
  • Safer test

  • Test safety

    Comprehensive software and hardware protection measures to prevent misoperation and abnormal conditions, to ensure the safety of testing backconnection protection, wire protection, work step self-inspection, trend protection, etc.
  • Data security

    When the ac power supply is interrupted, the device automatically records the power supply. After the power supply is restored, the device can resume the test and data is not interrupted. The dual-data technology prevents the loss of test data caused by manual or accidental operations.
  • Battery module testing equipment series
  • Charging voltage
    0V~60V
  • Discharge voltage
    5V~60V
  • Voltage accuracy
    ±0.05%F.S.
  • Output current range
    0.1A~100A
  • Accuracy of current
    ± 0.05%F.S.
  • Charge and discharge efficiency
    85%
  • Response time of charge and discharge current
    ≤5ms
  • Charge and discharge current conversion time
    ≤10ms
  • Charging voltage
    0V~60V
  • Discharge voltage
    5V~60V
  • Voltage accuracy
    ±0.05%F.S.
  • Output current range
    0.1A~300A
  • Accuracy of current
    ± 0.05%F.S.
  • Charge and discharge efficiency
    85%
  • Response time of charge and discharge current
    ≤5ms
  • Charge and discharge current conversion time
    ≤10ms
  • Charging voltage
    0V~60V
  • Discharge voltage
    5V~60V
  • Voltage accuracy
    ±0.05%F.S.
  • Output current range
    0.1A~600A
  • Accuracy of current
    ± 0.05%F.S.
  • Charge and discharge efficiency
    85%
  • Response time of charge and discharge current
    ≤5ms
  • Charge and discharge current conversion time
    ≤10ms
  • Charging voltage
    0V~120V
  • Discharge voltage
    5V~120V(Discharge voltage 0V can be customized)
  • Voltage accuracy
    ±0.05%F.S.
  • Output current range
    0.1A~100A
  • Accuracy of current
    ± 0.05%F.S.
  • Charge and discharge efficiency
    90%
  • Response time of charge and discharge current
    ≤5ms
  • Charge and discharge current conversion time
    ≤10ms
  • Charging voltage
    0V~120V
  • Discharge voltage
    5V~120V(Discharge voltage 0V can be customized)
  • Voltage accuracy
    ±0.05%F.S.
  • Output current range
    0.1A~300A
  • Accuracy of current
    ± 0.05%F.S.
  • Charge and discharge efficiency
    90%
  • Response time of charge and discharge current
    ≤5ms
  • Charge and discharge current conversion time
    ≤10ms
  • Charging voltage
    0V~120V
  • Discharge voltage
    5V~120V(Discharge voltage 0V can be customized)
  • Voltage accuracy
    ±0.05%F.S.
  • Output current range
    0.1A~600A
  • Accuracy of current
    ± 0.05%F.S.
  • Charge and discharge efficiency
    90%
  • Response time of charge and discharge current
    ≤5ms
  • Charge and discharge current conversion time
    ≤10ms
  • 지금 문의하세요

    Sinexcel에 대한 정보를 알고 싶으십니까? 귀하의 관심에 감사드리며 기꺼이 조언해 드리겠습니다.
    우리가 당신에게 연락할 수 있도록 몇 가지 정보를 제공해 주십시오.
    • 요금은 서비스 제공업체 및 국가/지역에 따라 다릅니다.
    • 독일 유선전화 및 모바일 네트워크에서는 무료입니다. 해외에서 온 전화,
               국제전화를 이용해주세요
  • Sinexcel ist für Ihre persönlichen Daten verantwortlich. Unsere Datenschutzerklärung beschreibt die verschiedenen Datenschutzrechte, die Sie haben, und wie Sie diese Rechte in Bezug auf die von uns verarbeiteten Daten ausüben können, wie z.B. das Recht auf Zugang oder Erhalt einer Kopie Ihrer Daten oder das Recht, die Löschung oder Korrektur Ihrer Daten zu verlangen. In einigen Fällen können Sie der weiteren Verarbeitung Ihrer Daten widersprechen, und wenn Sinexcel Sie um Ihre Zustimmung zur Datenverarbeitung gebeten hat, können Sie diese Zustimmung jederzeit zurückziehen.
    Weitere Einzelheiten darüber, wie wir personenbezogene Daten verwenden, und über Ihre Datenschutzrechte finden Sie in unserem vollständigen Datenschutzhinweis
  • 0755-8651-1588 sales@sinexcel.com